Kizlon Medical is The United Kingdom based leading manufacturers of medical devices served in the field of Hospitals, Biomedical industry, Pharmaceutical industry, Biotechnology industry, Education institutes and research laboratories.
Our aim is to achieve customer satisfaction by providing clinically superior and cost-effective solutions for improving patient life. We hold an extensive range of healthcare including medical monitors, diagnostic equipment, laboratory medical devices, measuring devices, life-supporting medical equipment, treatment devices, accessories, consumables and hospital furniture providing a comprehensive array of products for Medical and Hospital environment.
We assure quality and reliability of our products as all our equipment are clinically validated and tested by our engineers before dispatching the consignment. We have been accredited with standard certifications CE, ISO 9001: 2008 as per safety guidelines.
Length | 2050 ± 50 mm |
Width | 480 ± 50 mm |
Adjustable height (Min to Max) | (750 to 950 ) ± 50 mm |
Trendelenburg | ≥ 20 ° |
Image Sensor | 1/4″ Super HAD color CCD |
CCD Resolution (HD optional) | 8,00,000 pixels |
Horizontal Resolution | ≥ 470 TV lines |
Magnification | Optical : 10 x to 60 x Digital : Up to 128 x |
Light source | LED bulb |
Luminance | About 18.5 lumen |
Lens | Glass lens with 3 X magnification |
Ear Specula sizes | 2.4 mm 3 mm 4 mm 5 mm |
Type | Fully automated 3-part differential system |
Throughput | 30 samples/hr |
Principle of Operation | Impedance, SFT method |
Accuracy (CV %) | WBC(109/L) : 2.0 % RBC (1012/L) : 1.5 % HGB (g/L) : 1.5 % MCV (fL) : 0.5 % PLT (109/L) : 4.0 % |
Expression | Double-phase |
Construction | Food grade PP and Silicone, BPA free. |
Display | LCD display |
Modes | Massage and Expression |
Type | Neonatal |
Stroke volume | 150 ml |
Resuscitator volume | 250 ml |
Bag reservoir volume | 600 ml |
Type | Fully automated 5-part differential system |
Throughput | 60 samples/hr |
Principle of Operation | Impedance, Colorimetry |
Accuracy (CV %) | WBC (109/L) : (0 - 100) RBC (1012/L) : (0 - 1700) HGB (g/L) : (0 - 250) PLT(109/L) : (0 - 3000) |
Height adjustability | 450 mm to 700 mm |
Back-rest angle | 0° - 80° (±5°) |
Knee-rest angle | 0° - 40° (±5°) |
Trendelenburg angle | 0° - 12° |
Exposure Voltage | 50 kV ~ 125 kV |
Exposure Current | Small focus: (50, 100) mA Big focus: (50, 100, 200 and 300) mA |
Max. Output Voltage | 120 kV |
Max. Output Current | 300 mA (instant) |
Display size | 15-inch LCD screen |
Display depth | 250 mm |
Ultrasound modes | B, B+B, B+M, M, 4B |
TGC | Total gain, 8 segment TGC |
Illumination intensity | 60,000 lux ~ 120,000 lux |
Lamp holder diameter | 600 mm |
Light field | 100 mm ~ 280 mm |
Temperature increased | ≤ 12 °C |
Patient range | Adult, pediatric, neonate |
NIBP Measurement method | Oscillometric |
NIBP Measurement range | 0 kPa – 38.67 kPa (0 mmHg – 290 mmHg) |
NIBP Measurement mode | Arm Measurement |
Height adjustability | 350 mm - 700 mm |
Back-rest angle | 0° - 80° (±5°) |
Knee-rest angle | 0° - 40° (±5°) |
Construction | Electrostatic powder coated S.S. tube frame with ABS head and foot board |
Illumination Intensity (at 1 m) | ≥50,000 lux |
Bulb power | 125 W |
Power input | 150 VA |
Light source | Halogen bulb |
KVO Rate | 0.1 – 5ml/h (steps : 0.1ml/h) |
Injection Compliance | Adaptable for 5 syringe sizes |
Preset Volume Range | 0.1 ml – 1999.9 ml |
Occlusion System | 3-level alarming system |
Display Size | 10-inch screen |
Display Depth | ≥ 250 mm |
Ultrasound Modes | B, B+B, B+M, B+2M, M, 4B |
TGC | Total gain, 8 segment TGC |